{"entity":{"id":"sequencing-depth-and-coverage","kind":"term","name":"Sequencing depth and coverage","aka":[],"tldr":"Depth counts sequence observations at a position; breadth describes how much of a target meets a stated depth.","summary":"Depth is the number of aligned reads covering a base after stated filters; 40x means forty counted observations under those rules; depth without its counting rule is incomplete.","asOf":"2026-11-15","links":[{"label":"Guidelines for Validation of Next-Generation Sequencing-Based Oncology Panels: A Joint Consensus Recommendation of the Association for Molecular Pathology and College of American Pathologists.","url":"https://pubmed.ncbi.nlm.nih.gov/28341590/"},{"label":"samtools depth counting rules","url":"https://www.htslib.org/doc/samtools-depth.html"},{"label":"samtools coverage summary rules","url":"https://www.htslib.org/doc/samtools-coverage.html"}],"tags":[],"related":["ngs"],"cancers":[],"sections":[],"technologies":[],"targets":[],"drugs":[],"companies":[],"institutions":[],"pathways":[],"terms":[],"trials":[],"people":[],"bottlenecks":[],"keyPapers":[],"journals":[],"dependsOn":[],"notes":["Depth is the number of aligned reads covering a base after stated filters; 40x means forty counted observations under those rules; depth without its counting rule is incomplete.","Mean depth averages positions; coverage breadth is the fraction of a named target (denominator: target bases, not reads or cells) meeting a stated minimum depth; neither shows which important positions were missed.","Fictional report: mean 100x, 900 of 1,000 target bases at or above an illustrative 20x criterion gives 90% breadth, while the position of interest has 4 usable observations; 20x is not a clinical cutoff. The mean is a supplied report value: no full per-base profile is given from which to recompute it. Four read observations also do not prove four independent original molecules.","Read depth differs from molecular depth: overlapping pair ends and amplification copies inflate reads without adding independent fragments; HTSlib defaults are software definitions, not clinical validation criteria.","More sequencing cannot recover a region absent from the library or create independent molecules from duplicates; library complexity, input, preservation, capture and alignment limit usable evidence.","A negative report covers tested regions, detectable change classes and validated sensitivity; identical depths can support different detection limits; depth does not establish origin, function or actionability.","A narrow panel can be deep and a genome broad but thinner per position; territory asks where, depth asks how many.","Use an existing alignment file to calculate depth without consuming more tissue; recovering a more diverse library may require another aliquot. Retain reference regions, per-position counts, summary depth, breadth criterion and molecule-count rules. Capture bias, duplicate inflation and damaged input require controls and intended-use sensitivity/reproducibility validation; a summary criterion is separate from a detection limit.","In a separate fictional target, four usable aligned reads overlap position P, only two overlap Q, and none overlap R even though R was selected. Their local depths are 4x, 2x and 0x. R has no usable observations in this example; a position outside the assay design was not examined. These values establish neither a clinical threshold nor a variant-detection probability."],"category":"Genomics & genetics"},"route":"/terms/sequencing-depth-and-coverage/","neighbours":{"term":[{"id":"ngs","kind":"term","name":"Next-generation sequencing (NGS)","route":"/terms/ngs/"}]}}