# OnCo record image-guided-radiotherapy-daily-setup-verification (protocol). Data CC BY-NC 4.0, attribute "Data from OnCo (onco.cc)". Whole corpus: https://onco.cc/api/v1/onco.nt
@prefix schema: <https://schema.org/> .
@prefix onco: <https://onco.cc/ns#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

<https://onco.cc/protocols/image-guided-radiotherapy-daily-setup-verification/>
  a schema:MedicalGuideline ;
  onco:kind "protocol" ;
  schema:identifier "image-guided-radiotherapy-daily-setup-verification" ;
  schema:name "Image-guided verification of daily radiotherapy set-up: imaging, matching and correction"@en ;
  schema:alternateName "IGRT"@en, "image-guided radiotherapy"@en, "image guidance"@en, "daily imaging before radiotherapy"@en, "treatment verification imaging"@en, "cone-beam CT before treatment"@en, "CBCT match"@en, "portal imaging"@en, "kV imaging"@en, "image matching"@en, "online correction"@en, "offline correction"@en, "no action level protocol"@en, "couch shift"@en, "set-up error"@en, "on-treatment verification"@en ;
  schema:description "Before a radiotherapy treatment the radiographers often take a quick X-ray picture or scan on the treatment machine and compare it with the planning scan, to check that you are in the planned position. If the position is out, the couch is moved to correct it before the beam is switched on. How often this is done depends on the part of the body and the type of treatment."@en ;
  schema:url <https://onco.cc/protocols/image-guided-radiotherapy-daily-setup-verification/> ;
  schema:dateModified "2026-11-17"^^xsd:date ;
  onco:related <https://onco.cc/protocols/breast-radiotherapy-positioning-and-setup/>, <https://onco.cc/protocols/prostate-radiotherapy-bladder-and-rectal-preparation/>, <https://onco.cc/protocols/respiratory-motion-management-4d-ct-and-gating/>, <https://onco.cc/protocols/stereotactic-radiosurgery-and-sbrt-delivery-safeguards/>, <https://onco.cc/protocols/radiotherapy-patient-identification-and-time-out/>, <https://onco.cc/protocols/linear-accelerator-quality-assurance/>, <https://onco.cc/protocols/head-and-neck-radiotherapy-immobilisation-mask/>, <https://onco.cc/protocols/breath-hold-left-breast-radiotherapy/>, <https://onco.cc/protocols/radiotherapy-planning-ct-simulation/>, <https://onco.cc/technologies/surface-guided-radiotherapy/>, <https://onco.cc/technologies/adaptive-radiotherapy/> ;
  onco:technologies <https://onco.cc/technologies/in-room-imaging-systems/>, <https://onco.cc/technologies/imrt-igrt/> ;
  onco:terms <https://onco.cc/terms/radiotherapy/>, <https://onco.cc/terms/imrt-term/>, <https://onco.cc/terms/planning-target-volume/>, <https://onco.cc/terms/fiducial-markers/> .
