Safety and Feasibility of Repeated and Transient Blood-Brain Barrier Disruption by Pulsed Ultrasound in Patients with Recurrent Glioblastoma
Paper cited by one technology page, indexed on Europe PMC as PubMed record 30890548 and published in Clinical Cancer Research; the citing page links this DOI, which is how the record was matched.
Overview
Purpose: The blood-brain barrier (BBB) limits the efficacy of drug therapies for glioblastoma (GBM). Preclinical data indicate that low-intensity pulsed ultrasound (LIPU) can transiently disrupt the BBB and increase intracerebral drug concentrations.
Patients and methods: A first-in-man, single-arm, single-center trial (NCT02253212) was initiated to investigate the transient disruption of the BBB in patients with recurrent GBM. Patients were implanted with a 1-MHz, 11.5-mm diameter cranial ultrasound device (SonoCloud-1, CarThera). The device was activated monthly to transiently disrupt the BBB before intravenous carboplatin chemotherapy.
Results: Between 2014 and 2016, 21 patients were registered for the study and implanted with the SonoCloud-1; 19 patients received at least one sonication. In 65 ultrasound sessions, BBB disruption was visible on T1w MRI for 52 sonications. Treatment-related adverse events observed were transient and manageable: a transient edema at H1 and at D15. No carboplatin-related neurotoxicity was observed. Patients with no or poor BBB disruption ( n = 8) visible on MRI had a median progression-free survival (PFS) of 2.73 months, and a median overall survival (OS) of 8.64 months. Patients with clear BBB disruption ( n = 11) had a median PFS of 4.11 months, and a median OS of 12.94 months.
Conclusions: SonoCloud-1 treatments were well tolerated and may increase the effectiveness of systemic drug therapies, such as carboplatin, in the brain without inducing neurotoxicity. See related commentary by Sonabend and Stupp, p. 3750.
Indexed on Europe PMC as PubMed record 30890548 (DOI 10.1158/1078-0432.ccr-18-3643). Matched by DOI alone: one technology page cites this DOI among its external links (the pages are listed under Related), and this page was written so that the citation resolves inside OnCo. No figure has been checked by an editor.
One technology page on OnCo cites this paper by its DOI; this record gives the citation a page of its own so a reader can follow it without leaving OnCo. Read the abstract above alongside the citing page listed under Related; the record was created automatically from the Europe PMC entry and its figures have not been checked by hand.
- Matched to the citing OnCo records by DOI alone; the summary reproduces the Europe PMC abstract and no figure has been verified against the full paper.