The management of respiratory motion in radiation oncology report of AAPM Task Group 76
Paper cited by one technology page, indexed on Europe PMC as PubMed record 17089851 and published in Medical physics; the citing page links this DOI, which is how the record was matched.
Overview
This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external-beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy specific problems caused by respiratory motion, explains techniques that explicitly manage respiratory motion during radiotherapy and gives recommendations in the application of these techniques for patient care, including quality assurance (QA) guidelines for these devices and their use with conformal and intensity modulated radiotherapy. The technologies covered by this report are motion-encompassing methods, respiratory gated techniques, breath-hold techniques, forced shallow-breathing methods, and respiration-synchronized techniques. The main outcome of this report is a clinical process guide for managing respiratory motion. Included in this guide is the recommendation that tumor motion should be measured (when possible) for each patient for whom respiratory motion is a concern. If target motion is greater than 5 mm, a method of respiratory motion management is available, and if the patient can tolerate the procedure, respiratory motion management technology is appropriate. Respiratory motion management is also appropriate when the procedure will increase normal tissue sparing. Respiratory motion management involves further resources, education and the development of and adherence to QA procedures.
Indexed on Europe PMC as PubMed record 17089851 (DOI 10.1118/1.2349696). Matched by DOI alone: one technology page cites this DOI among its external links (the pages are listed under Related), and this page was written so that the citation resolves inside OnCo. No figure has been checked by an editor.
One technology page on OnCo cites this paper by its DOI; this record gives the citation a page of its own so a reader can follow it without leaving OnCo. Read the abstract above alongside the citing page listed under Related; the record was created automatically from the Europe PMC entry and its figures have not been checked by hand.
- Matched to the citing OnCo records by DOI alone; the summary reproduces the Europe PMC abstract and no figure has been verified against the full paper.